-40%

Schneider SW2524 Hybrid 3000 Watt Solar Inverter

$ 369.6

Availability: 87 in stock

Description

Description
Conext SW 3,000 watt 24VDC/120/240VAC Inverter
The Schneider Electric Conext SW inverter is perfect for off-grid and backup power systems.
Pure sine wave output
Built-in charger that can recharge your battery bank from a generator or other AC source.
Split phase AC output 120/240 volts
Can be set for 50Hz or 60Hz operation
Best in its class for functionality, user friendliness and cost effectiveness
Excellent load start capabilities with high 30-minute and 5-second surge power
Robust design through rigorous reliability testing (HALT)
Supports AC coupled and DC coupled off-grid and grid-tie architectures
Intelligent functionality enables self consumption with solar prioritization, peak shaving and, assisting small generators with heavy loads
Configures quickly into compact wall mounted system
Companion breaker panels integrate inverter with battery bank and solar charge controllers
Mounting bracket design makes hanging inverter on the wall easy
Please note:
The Schneider Electric SW inverters are rated for 240 volts AC output.  The inverter is not capable of delivering its full power output when delivering power to 120 volt devices.  The 2524-120 is capable of delivering a maximum of 1,800 Watts at 120 volts AC.
Features
Electrical Specifications-Inverter
Output power (continuous) at 25°C 3000 W
Output power (30 min) at 25°C 3300 W
Output power (5 sec) at 25°C 5000 W
Peak current 24.3 A
Output frequency 50 / 60 Hz selectable
Output voltage 120 / 240 Vac
Output wave form True sine wave
Optimal efficiency 91.5%
Idle consumption search mode <11>
Input DC voltage range 20 - 34 Vdc
AC connections Single / Split phase
Electrical Specifications- Charger
Output current 65A
Nominal output voltage 24 Vdc
Output voltage range 12 - 32 Vdc
Charge control 2 or 3 stage
Charge temperature compensation Yes - BTS included
Optimal efficiency 90%
AC input power factor > 0.98
Input current 9 A
Input AC voltage 120 / 240 Vac split phase
Input AC voltage range line to neutral 95 - 135 Vac single phase
Dead battery charge Yes
General Specifications
Tare loss 24 W
Compatible battery types FLA, Gel, AGM, Custom
Transfer relay rating 30 A
Transfer time (AC to inverter and inverter to AC) <1 cycle="" (16.7="">
Optimal operating temperature range -20°C to 60°C (-4°F to 140°F)
Storage ambient temperature range -40°C to 85°C (-40°F to 185°F)
Humidity Operation / storage < 95%="" rh,="" non="" />
Ingress protection rating Indoor only, IP20
Altitute (operating) 2000 m (6562 ft)