Outback Power Radian Series GSLC Load Centers
$ 306.23
- Description
- Size Guide
Description
Radian GSLC Load CentersThe
GS Load Center (GSLC)
is a wiring and circuit-protection enclosure that mounts under the Radian
inverter. It is available in multiple versions:
The base GSLC includes positive and negative main inverter busbars, a 500 A 50 mV shunt with negative
terminal bar, the main DC positive breaker plate, ground and neutral terminal bars, and two PV-positive terminal bars. It can also accommodate up to 18 AC or DC panel-mount breakers (ten top, eight bottom), two main 175 A DC breakers and a FLEXnetDC, which can be purchased separately. Up to two charge controllers can mount on the right side (mounting brackets sold seperately), and either the HUB4 or HUB10 can mount on the left side.
The
GSLC175-120/240
includes the base unit plus two 175 A DC main breakers, an AC output and
bypass breakers with interlock plate, AC grid and generator-input breakers (50 A two-pole), and six AC terminal bars (three black, three red). It can also accommodate ten additional panel-mount breakers, (purchased separately).
The
GSLC175-PV-120/240
works with the GS8048A inverters, or the GS4048A inverter with an extra
175 A breaker, and includes items in the 175-120/240 unit plus two 80 A PV array breakers, a two-pole GFDI 80 A breaker, three 500 A 50 mV shunts with shunt bus, and a FLEXnetDC. The GFDI acts as the breaker between the control and positive bus; there are no other breakers added for this purpose. It can also accommodate five additional panel-mount breakers, (purchased separately).
The
GSLC175-PV1-120/240
works ONLY with the GS4048A inverter and one charge control, and includes
one 175 ADC main breaker plus one 80 A PV breaker, one two-pole GFDI 80 A breaker, two 500 A 50 mV shunts with shunt bus, and a FLEXnetDC.
The
GSLC175-PV-300VDC
works with the GS8048A inverters, or the GS4048A inverter with an extra 175 A breaker, and two FM100 charge controls, and includes items in the 175-120/240 unit plus two PV array breakers, three 500 A 50 mV shunts with shunt bus, and a FLEXnetDC. The GFDI is built into the FM100 charge control.
The
GSLC175-PV1-300VDC
works ONLY with the GS4048A-01, and one FM100 charge control. It includes one 175 ADC main breakers plus one PV breakers, two 500 A 50 mV shunts with shunt bus, and a FLEXnetDC. The GFDI is built into the FM100 charge control.
The
AC bypass
assembly is only for use with a single Radian inverter. For multiple inverters, use the base GSLC with added DC and AC breakers as needed (no bypass) and use external transfer switches for bypass and external AC load centers for output combining and input distribution. One GSLC is required for each Radian inverter. Each 8 kW inverter requires two 175 A main DC breakers and each 4 kW inverter requires one.
The
GSLC175-AC-120/240 - GS Load Center factory pre-wired for AC-Coupled Applications, with inverter DC over-current protection and disconnect, dual AC inputs, grid-tie inverter connection and 120/240 VAC maintenance bypass.
The GSLC is not rated for outdoor use. Dimensions are 17"H x 16"W x 8.5"D. Weight is 26, 37, or
38 lbs. Listed to UL 1741 for U.S.A. and Canada.